Hamilton Company OxyFerm FDA 425 Electrochemical Oxygen Sensor Ref. 237454 (10000)M
In excellent cosmetic condition. See pictures for more detail. New Old Stock with/without box/packaging.


  FREE 30 DAY RETURNS


Manufacturer: Hamilton
Model: Oxyferm FDA 425


Specifications: The following specifications were taken from an online user manual or manufacturer's website and may not be specific to this item, please look at pictures carefully for items included and specifics.  These specifications are for reference only.

Hamilton Company
Product Category Dissolved Oxygen Sensors
Product Number 237454
Product Name OXYFERM FDA 425
Mounting Hand Held or Portable
Maximum Length 16.73 inch (425 mm)
Maximum Diameter/ Width 0.4724 inch (12 mm)
Response Time 60 seconds
Minimum Flow Rate 3 cm/sec (1.18 in/sec)

Sensor Family Parameter Sensor Output a-length Electrical Connector Measurement Principle Measuring Range
OxyFerm FDA
DO (Electrochemical)
Traditional: nA
425 mm
T82/D4
Electrochemical reduction of oxygen
10 ppb to 40 ppm (DO) or 0.2 to 1000 mbar (pO2)

Additional specifications

Drift at Room Temperature
< 1 % per week


Actual Dimensions: 20x1x1"
Actual Weight: 2 lbs



Sold as is with 30 day Right of Return, only pictured items included

Easy return/refund for any reason
Anacapa Equipment
If you happen to have any constructive criticism regarding the items in our listing feel free to message us, any information or suggestion is welcome.

RETURNS 
Anacapa Equipment Brokers, Inc. (“Seller”) strives to offer excellent customer service.   You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent.  We DO NOT ship internationally.  If you are using a freight forwarder then returns are VOID.  

SHIPPING                                                                                                               All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment.  We only charge actual shipping cost.  If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
LIMITED WARRANTY                                                                 
Buyer acknowledges that the equipment is being sold “as is" and without any warranty of merchantability or fitness for a particular use.  The entire risk as to the quality and performance of the equipment is with the Buyer.  Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair.  Buyer may inspect the equipment prior to purchase and placement of the order.  Failure to inspect prior to placement of an order is deemed a waiver of Buyer’s right to inspect.  Buyer is responsible for determining the suitability of the equipment for its application.  Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.  The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty.

INDEMNITY                                                                                                            
Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (“Indemnitees”) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller.  The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws.  Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California. 

Specifications

ManufacturerHamilton Company
ModelOxyFerm FDA 425
ConditionNew