Barksdale Temperature Switch L1X-H351S Single Setting Explosion Proof (4443)
Single setting, SPDT snap-action local mount, Explosion-Proof temperature Switch. Designed for Hazardous Areas, Class 1, Div. 1 & 2, Groups B, C, D; Class 2, groups E, F, G; Class 3. The Enclosure classifications are NEMA 4, 7, 9 and IP66 along with approvals UL and CSA.. Enclosed terminal strip with a tamper proof external adjustment. Switch is rated 10 amps 120 or 240 VAC.
|
- Manufacturer: Barksdale
- Model #: L1X-H351S
- Model: Temperature Switch with Single Set Point
- Description:This is a lightly used temperature switch. Explosion Proof. This item has an adjustable range of +100 to +225 Degrees F. The switch is also mounted to an assembly that has a custom hole for the shaft and two mounting port holes.
- Defects: Cosmetic wear present, paint deteriation on the left side.
Specifications:
- Media Temp Range:-100 to +400 F / -73 to +205 C
- Adjustable Range: +100+225F/+38+107C
The following is taken from manufacturer's website:
Technical specifications
General Specifications*
Accuracy: |
±1% of mid-60% of full range. At constant ambient +/- 0.5% of full scale. (Knob indication is reference only) |
Switch: Single Setting: Dual Setting: |
One (1) single pole double throw (SPDT) circuit.
|
Electrical Characteristics: |
All models incorporate Underwriters?? Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. |
Wetted Parts: |
304 stainless steel |
Electrical Connection: |
Single: 3-pin terminal strip
|
Electrical Ratings: |
AC value at 75% power factor ?X10 amps 125, 250 volts AC, 3 amps 480 volts AC. Automatically reset by snap-action of switch. |
Enclosure/Housing: |
Designed for hazardous locations: Class I, Division 1 & 2 NEMA 4, 7, 9 & IP65 tamper-proof external adjustment, enclosed terminal strip. |
Local Mount: |
Immersion length 2-1/16 inches |
Bulb & Capillary: |
6 and 12 foot length standard. |
Approvals:
UL (standard): CSA (standard):
ATEX (optional): |
Underwriters’ Laboratories, Inc. and Canadian Standard Assoc. are listed under Temperature indicating and regulating equipment, for use in hazardous locations, Class I, Groups B, C and D; Class II, Groups E, F and G.
File No. E58658, Guide No. XBDV File No. LR34556, Guide 400-E-O.8. Class 4868. EX models are ATEX marked as follows: CE 0081, ISSeP 08 ATEX024X Ex II 2G D, Ex db IIC T6 Gb Ex tb IIIC T80°C Db IP66 -40°C ≤ Tamb ≤ +75°C |
Temperature Range: |
See product confi gurator |
Adjustment: |
Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. (Knob indication is reference only) |
Standard Options/ Modifications: |
For thermowels, split nuts and union connections, see accessory pages. |
Weight: |
Single - approximate 3.0 lbs.. |
* See Product Confi gurator for additional options. |
Wiring Code
Lead
Circuit #1
Circuit #2
Normally Closed |
Blue |
Orange |
Common |
Purple |
Brown |
Normally Open |
Red |
Yellow |
Sold as is with 30 day Right of Return, only pictured items included Easy return/refund for any reason Anacapa Equipment
RETURNS Anacapa Equipment Brokers, Inc. (“Seller”) strives to offer excellent customer service. You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent. We DO NOT ship internationally. If you are using a freight forwarder then returns are VOID. SHIPPING All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment. We only charge actual shipping cost. If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally. IF you are using a freight forwarder then returns are VOID. LIMITED WARRANTY Buyer acknowledges that the equipment is being sold “as is" and without any warranty of merchantability or fitness for a particular use. The entire risk as to the quality and performance of the equipment is with the Buyer. Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair. Buyer may inspect the equipment prior to purchase and placement of the order. Failure to inspect prior to placement of an order is deemed a waiver of Buyer’s right to inspect. Buyer is responsible for determining the suitability of the equipment for its application. Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased. The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty. INDEMNITY Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (“Indemnitees”) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller. The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws. Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California.
|
|