Waters Autosampler 2707 LC LC/MS Sample Management System 186004462 (4971)

Waters Autosampler 2707 LC LC/MS Sample Management System 186004462 (4971)

$2,000 (USD)

or Best Offer

Location:Goleta, CA

orCall (805)-6364334

Description

 
 
Waters Autosampler 2707 186004462 LC LC/MS Sample Management System (4971)W
Good cosmetic condition with some signs of use.  Unit powers on. Upon startup the two well trays move to the back of the unit. There is no light to indicate that the unit is on. Front panel opens and closes smoothly. No visible signs of errors. May require calibration. See pictures for more detail.

 

  • Manufacturer: Waters
  • Model #: 2707 186004462
  • Description: The 2707 Autosampler is a versatile, compact sample management system that makes highly precise and reproducible injections of samples into your LC or LC/MS system. It is ideally suited for laboratories where reduced carryover, maximized repeatability, high accuracy, and application flexibility are of concern. (Taken from manufacturer website).
  • Includes two 96 well plates and Wash/ Solvent bottle (see pictures)
(Taken from manufacturer website).

Features: 

  • Compact design yet easily serviceable
  • High-resolution syringe control for high-precision injections
  • Interchangeable fixed-volume sample loops
  • Variable-volume partial-loop injection capability
  • Optional sample cooling for consistent results
  • Pressure-assisted sample aspiration injection capability
  • Use of plates or vials, alone or in combination, for varied sampling formats
Sampling 
  • Sample capacity: 2 microtiter plates according to SBS standards; 96-well high/low and 384-well low formats, 48-vial or 12-vial trays; any combination of plates is allowed
  • Loop Volumes: 5, 10, 20, 100 (standard), and 500 μL; 10 mL loop (standard) for prep option
  • Headspace pressure: Built-in compressor, only used for vials with septa
  • Switching Time Injection Valve: Electrically <100 msec
Programming
  • Injection Methods: Full loop, partial loopfill, and partial loop needle overfill
  • Injection Volume: 0 to 9999 μL (with 1 μL increment), depending on system settings
  • Maximum Injection Volume: Full loop = loop volume, Partial loop needle overfill = 1/2 x loop volume, Partial loopfill = (loop volume - 3 x needle volume)/2
  • Injections per vial/well: Maximum 99 Injections
  • Analysis Time: Maximum 650 Minutes
  • Wash: Wash between injections, programmable volumes
  • Priority Sample: Programmable 
Specifications: 
  • HPLC Autosampler
  • Power Requirements: 95 to 240 VAC ± 10%; 50 to 60 Hz; 200VA
  • Viscosity Range: 0.1 to 5.0 cP
  • Back Pressure (Max): 5000 psi (345 bar)
  • Audible Noise Level: <65 dBA
  • Working Temperature: 10 to 40°C (indoor use only)
  • Storage Temperature: –25 to +60 °C
  • Humidity: 20% to 80% RH
  • Altitude: Up to 2000 m
  • Inputs:
    • ​Ethernet
    • RS-232 I/O connecter
  • Dimensions: 12''(L) x 20''(W) x 14"(H)


Crating Fee: Ask For Quote



Sold as is with 30 day Right of Return, only pictured items included
Easy return/refund for any reason
Anacapa Equipment

RETURNS 
Anacapa Equipment Brokers, Inc. (“Seller”) strives to offer excellent customer service.   You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent.  We DO NOT ship internationally.  If you are using a freight forwarder then returns are VOID.  

SHIPPING                                                                                                               All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment.  We only charge actual shipping cost.  If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
LIMITED WARRANTY                                                                 
Buyer acknowledges that the equipment is being sold “as is" and without any warranty of merchantability or fitness for a particular use.  The entire risk as to the quality and performance of the equipment is with the Buyer.  Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair.  Buyer may inspect the equipment prior to purchase and placement of the order.  Failure to inspect prior to placement of an order is deemed a waiver of Buyer’s right to inspect.  Buyer is responsible for determining the suitability of the equipment for its application.  Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.  The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty.

INDEMNITY                                                                                                            
Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (“Indemnitees”) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller.  The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws.  Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California. 

 

 
 







 
 
Waters Autosampler 2707 186004462 LC LC/MS Sample Management System (4971)W
Good cosmetic condition with some signs of use.  Unit powers on. Upon startup the two well trays move to the back of the unit. There is no light to indicate that the unit is on. Front panel opens and closes smoothly. No visible signs of errors. May require calibration. See pictures for more detail.

 

  • Manufacturer: Waters
  • Model #: 2707 186004462
  • Description: The 2707 Autosampler is a versatile, compact sample management system that makes highly precise and reproducible injections of samples into your LC or LC/MS system. It is ideally suited for laboratories where reduced carryover, maximized repeatability, high accuracy, and application flexibility are of concern. (Taken from manufacturer website).
  • Includes two 96 well plates and Wash/ Solvent bottle (see pictures)
(Taken from manufacturer website).

Features: 

  • Compact design yet easily serviceable
  • High-resolution syringe control for high-precision injections
  • Interchangeable fixed-volume sample loops
  • Variable-volume partial-loop injection capability
  • Optional sample cooling for consistent results
  • Pressure-assisted sample aspiration injection capability
  • Use of plates or vials, alone or in combination, for varied sampling formats
Sampling 
  • Sample capacity: 2 microtiter plates according to SBS standards; 96-well high/low and 384-well low formats, 48-vial or 12-vial trays; any combination of plates is allowed
  • Loop Volumes: 5, 10, 20, 100 (standard), and 500 μL; 10 mL loop (standard) for prep option
  • Headspace pressure: Built-in compressor, only used for vials with septa
  • Switching Time Injection Valve: Electrically <100 msec
Programming
  • Injection Methods: Full loop, partial loopfill, and partial loop needle overfill
  • Injection Volume: 0 to 9999 μL (with 1 μL increment), depending on system settings
  • Maximum Injection Volume: Full loop = loop volume, Partial loop needle overfill = 1/2 x loop volume, Partial loopfill = (loop volume - 3 x needle volume)/2
  • Injections per vial/well: Maximum 99 Injections
  • Analysis Time: Maximum 650 Minutes
  • Wash: Wash between injections, programmable volumes
  • Priority Sample: Programmable 
Specifications: 
  • HPLC Autosampler
  • Power Requirements: 95 to 240 VAC ± 10%; 50 to 60 Hz; 200VA
  • Viscosity Range: 0.1 to 5.0 cP
  • Back Pressure (Max): 5000 psi (345 bar)
  • Audible Noise Level: <65 dBA
  • Working Temperature: 10 to 40°C (indoor use only)
  • Storage Temperature: –25 to +60 °C
  • Humidity: 20% to 80% RH
  • Altitude: Up to 2000 m
  • Inputs:
    • ​Ethernet
    • RS-232 I/O connecter
  • Dimensions: 12''(L) x 20''(W) x 14"(H)


Crating Fee: Ask For Quote



Sold as is with 30 day Right of Return, only pictured items included
Easy return/refund for any reason
Anacapa Equipment

RETURNS 
Anacapa Equipment Brokers, Inc. (“Seller”) strives to offer excellent customer service.   You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent.  We DO NOT ship internationally.  If you are using a freight forwarder then returns are VOID.  

SHIPPING                                                                                                               All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment.  We only charge actual shipping cost.  If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
LIMITED WARRANTY                                                                 
Buyer acknowledges that the equipment is being sold “as is" and without any warranty of merchantability or fitness for a particular use.  The entire risk as to the quality and performance of the equipment is with the Buyer.  Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair.  Buyer may inspect the equipment prior to purchase and placement of the order.  Failure to inspect prior to placement of an order is deemed a waiver of Buyer’s right to inspect.  Buyer is responsible for determining the suitability of the equipment for its application.  Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.  The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty.

INDEMNITY                                                                                                            
Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (“Indemnitees”) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller.  The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws.  Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California. 

 

 
 

Specifications

ManufacturerWaters
Model2707 186004462
ConditionUsed
Stock Number4971