Regular price $ 3,500.00 Sale

Condition: Used

Condition Details: Powers, Pulses, reacts to all push button commands. Great cosmetic condition with minimal usage.

The ECM® 630 is an exponential decay wave electroporation generator providing a broad range of voltage and time constant for full flexibility in varying applications. The ability to select the resistance and capacitance values and adjust the range of voltages is the key to achieving the optimal time constants and field strengths needed for efficient transformation of prokaryotes and eukaryote transfection. This system is an outstanding value for researchers working with bacteria, yeast, stem cell transfection, plant transformation and insect transfection. Flexibility is important to a researcher, so BTX has designed a plug and play system for our ECM® 630 system to transition between standard cuvettes and to a 96-well electroporation plate using our High Throughput plate handler.
 
 

BTX Harvard Apparatus ECM 630 Electro 
Cell Manipulator Safety Stand 630B
 (4636) 
  • Manufacturer: BTX Harvard Apparatus 
  • Model #: ECM 630 45-0051
  • Model: Electro Cell Manipulator
  • Description: The ECM® 630 is an exponential decay wave electroporation generator providing a broad range of voltage and time constant for full flexibility in varying applications. The ability to select the resistance and capacitance values and adjust the range of voltages is the key to achieving the optimal time constants and field strengths needed for efficient transformation of prokaryotes and eukaryote transfection. This system is an outstanding value for researchers working with bacteria, yeast, stem cell transfection, plant transformation and insect transfection. Flexibility is important to a researcher, so BTX has designed a plug and play system for our ECM® 630 system to transition between standard cuvettes and to a 96-well electroporation plate using our High Throughput plate handler.
  • Specifications:
  • Voltage range of 10 V to 500 V with 1 V resolution and 1 µF, 25 µF to 3275 µF in 25 µF increments. 25 µ to 1575 µ, 25 µ resolution with “none" setting 
     
  • Voltage range of 50 V to 2500 V with 5 V resolution and either 25 µF or 50 µF, 25 µ to 1575 µ with 25 µ resolution Over 300 BTX protocols may be duplicated with this instrument

Sold as is with 30 day Right of Return, only pictured items included
 
Easy return/refund for any reason

Anacapa Equipment
    
RETURNS
Anacapa Equipment strives to offer excellent customer service.   You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items must be received in the same condition as sent.  We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
 
SHIPPING     
All equipment purchased is shipped within one (1) day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment.  We only charge actual shipping cost.  If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
 
LIMITED WARRANTY
Buyer acknowledges that the equipment is being sold “as is" and without any warranty of merchantability or fitness for a particular use.  Buyer may inspect the equipment prior to purchase and placement of the order prior to inspection is deemed a waiver of Buyer’s right to inspect.  Buyer is responsible for determining the suitability of this product for its application.  Anacapa Equipment Brokers, Inc. assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the unit will be installed and operated by qualified personnel. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.  The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty.
 
DISCLAIMER
This equipment is not intended to be used, and should not be used in human experimentation, nor should this instrument be applied to humans in any way.
 
 
 