Bio-Rad Luminex Bio-Plex 200 Bio-Plex High Throughput Fluidics (HTF) Multiplex Array System Suspension Array analyzer Environment conditions Operating temperature: 15–30°C (59–86°F) Operating humidity, noncondensing: 20–80% Operating altitude: Designed to operate at up to 2,000 m (6,600') mean sea level Compensatory range: ±2°C UL installation category: UL Installation Category II, as defined in Annex J of UL 3101–1 Pollution degree: UL Pollution Degree 2, as defined in Section 3.7, 3.2, of UL 3101–1 Bio-Plex Array Reader Specifications Input voltage range: 100–240 V, 1.5 A, 47 – 63 Hz Physical dimensions 43 cm x 51cm x 23cm Weight: 60lbs Lasers Reporter laser: 532 nm, >10 mW, frequency-doubled diode; 30 x 60 µm elliptical beam Classification laser: 635 nm, 10 mW, diode; 30 x 60 µm elliptical beam Fluidics Sheath flow rate, µl/sec: 90 Cuvette: 200 µm square flow channel Sample injection rates, µl/sec: 60 Electronics Reporter channel detection: Photomultiplier tube, A/D resolution 14 bits Classification and doublet discriminator channel detection: Avalanche photodiodes with temperature compensation, A/D resolution 12 bits Communication interface: RS–232 Signal Processing Measurement resolution: 15 bits effective Processor modes: Linear, with logarithmic or linear display option Dynamic range, dB: 70 Bio-Plex Microplate Platform Specifications Input voltage range: 100–240 V, 1.8 A, 47–63 Hz Physical dimensions: 44cm x 61cm x 8cm Weight: 32 Communications interface: RS–232 Plate capacity: One 96-well microtiter plate, ≤0.75
 
 
Bio-Rad Luminex Bio-Plex 200 Suspension Array Analyzer With HTF (5924) Z R
Great cosmetic condition. Powers on. Unable to test instrument capabilities. Do not have software. Includes Bio-plex Reader Magnet. See pictures for more detail.
 
  • Manufacturer: Bio-Rad Luminex
  • Model #: Bio-Plex 200
  • Description: 
    • Bio-Rad Luminex
    • Bio-Plex 200
    • Bio-Plex High Throughput Fluidics (HTF) Multiplex Array System
    • Suspension Array analyzer
       
  • Environment conditions  
    • Operating temperature: 15–30°C (59–86°F)
    • Operating humidity, noncondensing: 20–80%
    • Operating altitude: Designed to operate at up to 2,000 m (6,600') mean sea level
    • Compensatory range: ±2°C
    • UL installation category: UL Installation Category II, as defined in Annex J of UL 3101–1
    • Pollution degree: UL Pollution Degree 2, as defined in Section 3.7, 3.2, of UL 3101–1
  • Bio-Plex Array Reader Specifications  
    • Input voltage range: 100–240 V, 1.5 A, 47 – 63 Hz
    • Physical dimensions 43 cm x 51cm x 23cm
    • Weight: 60lbs
  • Lasers  
    • Reporter laser: 532 nm, >10 mW, frequency-doubled diode; 30 x 60 µm elliptical beam
    • Classification laser: 635 nm, 10 mW, diode; 30 x 60 µm elliptical beam
  • Fluidics  
    • Sheath flow rate, µl/sec: 90
    • Cuvette: 200 µm square flow channel
    • Sample injection rates, µl/sec: 60
  • Electronics  
    • Reporter channel detection: Photomultiplier tube, A/D resolution 14 bits
    • Classification and doublet discriminator channel detection: Avalanche photodiodes with temperature compensation, A/D resolution 12 bits
    • Communication interface: RS–232
  • Signal Processing  
    • Measurement resolution: 15 bits effective
    • Processor modes: Linear, with logarithmic or linear display option
    • Dynamic range, dB: 70
  • Bio-Plex Microplate Platform Specifications  
    • Input voltage range: 100–240 V, 1.8 A, 47–63 Hz
    • Physical dimensions: 44cm x 61cm x 8cm
    • Communications interface: RS–232
    • Plate capacity: One 96-well microtiter plate, ≤0.75
       

Sold as is with 30 day Right of Return, only pictured items included
 
Easy return/refund for any reason

Anacapa Equipment
    
RETURNS
Anacapa Equipment strives to offer excellent customer service.   You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items must be received in the same condition as sent.  We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
 
SHIPPING     
All equipment purchased is shipped within one (1) day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment.  We only charge actual shipping cost.  If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
 
LIMITED WARRANTY
Buyer acknowledges that the equipment is being sold “as is” and without any warranty of merchantability or fitness for a particular use.  Buyer may inspect the equipment prior to purchase and placement of the order prior to inspection is deemed a waiver of Buyer’s right to inspect.  Buyer is responsible for determining the suitability of this product for its application.  Anacapa Equipment Brokers, Inc. assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the unit will be installed and operated by qualified personnel. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.  The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty.
 
DISCLAIMER
This equipment is not intended to be used, and should not be used in human experimentation, nor should this instrument be applied to humans in any way.
 
 
 







Get images that
make Supersized seem small.


THE simple solution for eBay sellers.