Condition Details: Responds to all commands, digital read out good, displays pulse results.

The BioRad Gene Pulser Xcell Electroporation System is a flexible, modular electroporation system that can transfect all cell types, from primary and stem cells to bacteria and yeast. Electroporation is the most efficient method available for gene expression analysis for the widest range and variety of cell types. This easy to program electroporation system comes with a convenient preset protocol library, including most bacterial and mammalian cell types, immortal and primary cells. This electroporator has the capacity to store and recall parameters in up to 100 experiments to aid in troubleshooting, while pulse trac circuitry and arc protection features ensure reproducibility and sample protection.
 
 
Bio-Rad Gene Pulser XCell Electroporation System CE / PC Module ShockPod 
(4616)
 
  • Manufacturer: Bio-Rad
  • Model: Gene Pulser XCell 
  • Working condition, responds to input, digital display good condition.
  • Defects: Small green tab is missing on the ShockPod unit, does not affect function.
  • Includes All Items Pictured:
            Main Unit
            PC Module
            CE Module
            Shock Pod
            Power Cord
            User Manual Available Online
  • Specifications:
  1. Outputs Waveform: Exponential or Square
  2. Voltage: 10–3,000 V
  3. Capacitance: 10–500 V, 25–3,275 µF in 25 µF increments 500–3,000 V, 10, 25, 50 µF
  4. Resistance (parallel): 50–1,000 ? in 50 ? increments, plus infinity
  5. Sample Resistance : 20 ? minimum at 10–2,500 V 600 ? minimum at 2,500–3,000 V
  6. Square-Wave Timing: 10–500 V: 0.05–10 ms in 0.05 ms increments, 10–100 ms pulse in 1 ms increments, 1–10 pulses, 0.1–10 sec interval
    500–3,000 V: 0.05–5 ms in 0.05 ms increments, 1–2 pulses, 5 sec minimum interval
  7. Input Voltage: 100–120 VAC or 220–240 VAC, 50/60 Hz
  8. Power: Maximum 240 W (during short charging periods)
  9. Operating Environment: Temperature 0–35°C, humidity 0–95% (noncondensing)
  10. Regulatory: Safety EN 61010, EMC EN 61326 Class A
  11. Dimensions (L x W x H) :  12x12x11
  12. Weight: 27 lbs
Sold as is with 30 day Right of Return, only pictured items included
 
Easy return/refund for any reason

Anacapa Equipment
    
RETURNS
Anacapa Equipment strives to offer excellent customer service.   You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items must be received in the same condition as sent.  We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
 
SHIPPING     
All equipment purchased is shipped within one (1) day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment.  We only charge actual shipping cost.  If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
 
LIMITED WARRANTY
Buyer acknowledges that the equipment is being sold “as is" and without any warranty of merchantability or fitness for a particular use.  Buyer may inspect the equipment prior to purchase and placement of the order prior to inspection is deemed a waiver of Buyer’s right to inspect.  Buyer is responsible for determining the suitability of this product for its application.  Anacapa Equipment Brokers, Inc. assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the unit will be installed and operated by qualified personnel. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.  The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty.
 
DISCLAIMER
This equipment is not intended to be used, and should not be used in human experimentation, nor should this instrument be applied to humans in any way.
 
 
 






Pictures sell!
Auctiva offers Free Image Hosting and Editing.


The complete eBay Selling Solution.