Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298
Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298
Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298
Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298
Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298
Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298
Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298
Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298
Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298

Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS 6298

Regular price $ 2,000.00 Sale

Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS (6298) R In great cosmetic condition. Turns on and buttons and screen work well. Error D16 (Unable to recognize rotor) when we tried to test. See pictures for more detail. Manufacturer: Avanti Model #: J-26 XPI Model: High Performance Centrifuge 240 V 24 A 50/60 Hz Cat#: 393127 Dimensions: Weight: 290 kg (640 lb) Length: 102 cm (40.25 in.) Width: 71 cm (28 in.) Height: with door closed — 86 cm (34 in.) to top of control head — 116 cm (45.5 in.) to top of open door — 149 cm (58.5 in.) Specifications Description Speed Setting range: — 100 to 26,000 RPM or equivalent RCF (in 100 g increments) Elutriation speed setting range: — 0 to 5000 RPM (in 10-RPM or 10 g increments) Speed display: — from 0 to 10,000 RPM, display indicates actual rotor speed 10 RPM; from 10,000 to 26,000 RPM, indicates actual rotor speed 0.1%, or equivalent RCF Speed Control Low speed (2000 RPM) control = ±10 RPM High speed (Max/Rotor) control = ±0.1 RPM Time Setting range: — 1 min to 99 hr 59 min, 2t, or continuous (hold) Actual display: — Indicates time remaining (timed run), 2t, or elapsed time (hold run) 2t setting range: — up to 9.99 1014 radians squared per second 2t actual display: — indicates accumulated centrifugal effect to 3 significant digits (in exponential notation) Temperature Setting range: –10 to +40°C (in 1°C increments) Accuracy: — rotor temperature controlled to within 2°C of set temperature (after equilibration)a Ambient temperature range: — 16 to 38°C (60 to 100°F)b Cooling fluid: — refrigerant 404A (HFC) Acceleration maximum, slow, or timed (1 to 10 min from 0 to 500 RPM) Deceleration maximum, slow, timed (1 to 10 min from 500 to 0 RPM), or off
 
 
Beckman Coulter Avanti J-26S XPI High Performance Ultracentrifuge FOR PARTS (6298) R
In great cosmetic condition. Turns on and buttons and screen work well. Error D16 (Unable to recognize rotor) and D6? High Speed Error, contact service, when we tried to test. See pictures for more detail.  Cools to temperature set, and spins to 500 RPM then throws error using a JA-18 Rotor.
  • Manufacturer: Avanti 
  • Model #: J-26S XPI
  • Model: High Performance Centrifuge
  • 240 V
  • 24 A
  • 50/60 Hz
  • Cat#: 814538
  • Dimensions:
    • Weight: 290 kg (640 lb)
    • Length: 102 cm (40.25 in.) 
    • Width: 71 cm (28 in.)
    • Height:
      • with door closed — 86 cm (34 in.)
      • to top of control head — 116 cm (45.5 in.)
      • to top of open door — 149 cm (58.5 in.) 
  • Specifications Description
    • Speed
      • Setting range: — 100 to 26,000 RPM or equivalent RCF (in 100  g increments)
      • Elutriation speed setting range: — 0 to 5000 RPM (in 10-RPM or 10 g increments)
      • Speed display: — from 0 to 10,000 RPM, display indicates actual rotor speed 10 RPM; from 10,000 to 26,000 RPM, indicates actual rotor speed 0.1%, or equivalent RCF
    • Speed Control
      • Low speed (2000 RPM) control = ±10 RPM
      • High speed (Max/Rotor) control = ±0.1 RPM Time
      • Setting range: — 1 min to 99 hr 59 min, 2t, or continuous (hold)
      • Actual display: — Indicates time remaining (timed run), 2t, or elapsed time (hold run)
      • 2t setting range: — up to 9.99  1014 radians squared per second
      • 2t actual display: — indicates accumulated centrifugal effect to 3 significant digits (in exponential notation)
    • Temperature
      • Setting range: –10 to +40°C (in 1°C increments)
      • Accuracy: — rotor temperature controlled to within 2°C of set temperature (after equilibration)a
      • Ambient temperature range: — 16 to 38°C (60 to 100°F)b
      • Cooling fluid: — refrigerant 404A (HFC)
      • Acceleration maximum, slow, or timed (1 to 10 min from 0 to 500 RPM)
      • Deceleration maximum, slow, timed (1 to 10 min from 500 to 0 RPM), or off

Sold as is with 30 day Right of Return, only pictured items included
 
Easy return/refund for any reason

Anacapa Equipment
    
RETURNS
Anacapa Equipment strives to offer excellent customer service.   You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items must be received in the same condition as sent.  We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
 
SHIPPING     
All equipment purchased is shipped within one (1) day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment.  We only charge actual shipping cost.  If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost. We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.  
 
LIMITED WARRANTY
Buyer acknowledges that the equipment is being sold “as is” and without any warranty of merchantability or fitness for a particular use.  Buyer may inspect the equipment prior to purchase and placement of the order prior to inspection is deemed a waiver of Buyer’s right to inspect.  Buyer is responsible for determining the suitability of this product for its application.  Anacapa Equipment Brokers, Inc. assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the unit will be installed and operated by qualified personnel. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.  The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty.
 
 
 







Pictures sell!
Auctiva offers Free Image Hosting and Editing.


THE simple solution for eBay sellers.